Shahar Shelly MD, Nicola Maggio MD PhD, Marina Boxer MD, Ilan Blatt MD, David Tanne MD and David Orion MD

Background: Computed tomography (CT) brain perfusion is a relatively new imaging method that can be used to differentiate patients following epileptic seizures in the setting of acute neurological deficits (e.g., hemiparesis, hemiplegia, hemianopsia, aphasia) who arrive at the emergency room with a suspected stroke.

Objectives: To evaluate brain perfusion changes in patients who had an epileptic seizure.

Methods: We retrospectively identified 721 patients who presented at our stroke center between 2012 and 2015 with a suspected acute stroke and underwent examination thorough a stroke protocol, including cerebral CT perfusion (CTP) and CT angiography (CTA) within 8 hours from the onset of symptoms. 

Results: Out of 721 patients, 25 presented with ictal electroencephalography (EEG) findings within 24–72 hours from symptom onset without evidence of vascular occlusion on CTA. While 15 patients had to be excluded from the study due to concomitant brain pathology, we found a specific reduction in cerebral blood volume and cerebral blood flow occurring at the ictal zone, which was identified by a post hoc EEG investigation. 

Conclusions: Our study shows that CTP is an easily accessible tool in emergency department setting for the detection of changes in blood flow dynamics among postictal patients. Thus, we propose the use of CTP in emergency settings to discriminate between postictal changes and acute vascular events. 

 

June 2010
A. Itsekson, D. Shepshelovich, A. Kanevsky and D.S. Seidman
Background: Non-invasive screening tests may allow early diagnosis and prompt treatment, thereby potentially reducing morbidity and mortality and reducing costs for the community.  This may be especially important for gynecologic pathologies that are difficult to promptly diagnose, such as endometriosis or ovarian cancer.

Objectives: To evaluate the reliability of measuring skin resistance using the Medex Test for screening and diagnosis of gynecologic pathologies in a blinded single-center study.

Methods: We enrolled 150 patients: 59 with a functional disorder and 91 with an organic disease. Measurements were carried out in all patients and the results were analyzed separately by a second physician who was blinded to the patients’ diagnosis.

Results: A high correlation was found between the clinical diagnosis and the results of the measurement of electrical skin resistance, with a specificity of 76.3% (45/59) for functional disorders and a sensitivity of 85.7% (78/91) for organic disorders, positive predictive value of 84.8% (78/92) and negative predictive value 77.6% (45/58). The kappa value for the results was 0.622, representing a value much better than expected randomly.

Conclusions: The Medex Test has a good specificity and a high sensitivity for the diagnosis of gynecologic disorders. Further prospective studies are needed to validate these preliminary findings.

October 2005
E. Zimlichman, A. Lahad, A. Aron-Maor, A. Kanevsky and Y. Shoenfeld.
 Background: As complementary and alternative medicine is gaining popularity among health consumers, diagnostic screening tools based on neuroreflexology are also being developed. These techniques, which are based on the rationale that measurement of electrical impedance of specific dermatomes reflects corresponding internal organ pathologies, have not yet been the subject of conventional scientific research.

Objectives: To determine the effectiveness of a neuroreflexology-based screening test, specifically the Medex device (Medex Screen Ltd.), for diagnosing patients undergoing conventional internal organ assessment, in a hospital setting.

Methods: Patients admitted to an internal medicine department, who met the inclusion criteria and agreed to participate, underwent conventional medical evaluation that included past medical history and physical examination. Another examination was conducted by a second physician using the Medex device to determine internal organ pathologies. A third researcher compared the actual “conventional” diagnosis with the Medex device output using standard statistical analysis.   

Results: Overall, 150 patients participated in the study. Correlation was significant for all categories (P < 0.01) except for blood and lymphatic disease. A high sensitivity (>70%) was measured for cardiovascular, respiratory, gastrointestinal and genitourinary diseases. The highest measure of agreement, as represented by the Cohen-Kappa factor, was found for respiratory disease (0.57).

Conclusions: Although the exact mechanism is not entirely clear, measurement of electroskin impedance of dermal-visceral zones has the potential to serve as a screening tool for inner organ pathologies. Further research should be conducted to create more evidence to support or dispute the use of this technique as a reliable diagnostic tool.

February 2000
Dan Nemet, MD, Baruch Wolach, MD, Joanne Yacobovich, MD and Alon Eliakim, MD